Setup 25xxx tablet with AutoCAD 13 in
Windows 3.x
Setup 25xxx tablet with AutoCAD 13 for Windows 3.x
A. Change Digitizer in AutoCAD to "System Pointing Device"
1. Enter Windows
2. Enter AutoCAD for Windows
3. Type CONFIG at the Command Line to Configure AutoCAD
4. Select "Configure Digitizer"
5. Do you want to select a different one? [Y]
6. Select "Current System Pointing Device"
7. Select option "0" and EXIT with changes
saved.
8. Exit AutoCAD for Windows and EXIT Windows.
B. Set Tablet Menu Settings to "AutoCAD as GTCO DP5" from the 2500 User's Manual
1. Refer to the "SETTING THE SOFT SWITCHES"
in your 2500 User's Manual for instructions on setting up
the
tablet for "AutoCAD as GTCO WITH GTCO MICRO DIGI-PAD
EMULATION."
2. Following are the menu settings required to enable
your digitizer to operate correctly:
Bank 1- 00000001
Bank 4- 00110100
Bank 2- 11001000
Bank 5- 01010100
Bank 3- 01110111
Bank 6- 00001000
(1 = Power Light is ON 0
= Power Light is OFF)
3. To change the menu settings:
a. Place the cursor on
the "BANK" block.
b. Select the block by
pressing the "0" button. The indicator light
will show which of the 8 banks is currently
active.
c. Select the block whose
number corresponds to the number of the
bank you wish to set.
d. Select the
"SETUP" block. The BANK indicator will go off and the
SETUP indicator will go on. The lights in
the
eight
numbered blocks now indicate the status of the switches in that bank.
e. The Pick 0 button will
toggle the light of each block to the
setting you wish.
f. Repeat steps
"a" through "e" for each bank requiring changes.
g. When finished, EXIT by
hitting the "SETUP" box again.
C. Enabling Support for Legacy Tablet and Two Input Devices
1. Enabling Legacy mode is neccessary to add support
for this model.
a. Switch to the Windows
directory by typing, "CD\WINDOWS" [ENTER].
b. Type EDIT SYSTEM.INI
[ENTER].
c. Locate the section
titled, "[pen driver]"
d. Edit the settings in
the [pen driver] section to appear
as follows:
pencom=x
;x= the COM port # the tablet uses
pentab=legacy
calaft=0
usebaud=9600
2. The Wintab™ driver supports two pointing
devices in Windows; a mouse and a
digitizer. It is possible to use
your current pointing
device as the mouse in Windows and use the CalComp
tablet in applications that utilize
the tablet. To
achieve this configuration, you will need
the mouse driver MOUSE.DRV loaded in the
SYSTEM.INI
file.
MOUSE.DRV needs to be specified
in the "[BOOT]" section on the "MOUSE.DRV="
line.
a. Change the mouse
line in the Boot section to read like the following:
[Boot]
mouse.drv=mouse.drv
b. Select FILE and
SAVE from the EDIT menu.
3. Start Windows
4. The tablet should be operating as your mouse
pointer.
D. Configure AutoCAD for the CalComp Driver
1. Start up Windows
2. Enter AutoCAD for Windows
3. Type CONFIG at the Command Line to Configure AutoCAD
4. Select "Configure Digitizer"
5. Do you want to select a different one? [Y]
6. Select "Wintab Compatible Digitizer-ADI 4.2 by
Autodesk Inc."
7. Type "0" to Exit to the drawing editor.
8. Keep configuration changes. [Y]
9. Select "Preferences" under the
"Options" menu.
10. Select "Digitizer/Mouse" under the Digitizer Input section.
11. Select [OK]
E. Configuring the AutoCAD Template (ACAD.MNU only)
1. Type "TABLET" [ENTER] at the command line.
2. Type "CFG" [ENTER]
3. Enter the number of menu areas.
4. Select "4" [ENTER]
5. AutoCAD will now ask you to select the, Upper Left, Lower Left, and Lower Right corners
of Menu Area 1 located
at the top of your AutoCAD
template.
6. Enter the number of columns for menu area 1:
7. Type "25" [Enter]
8. Enter the number of rows for menu area 1:
9. Type "9" [Enter]
10. Repeat steps 5-10 for menu areas 2, 3 and 4 using the columns and rows from the following
table:
a. MENU AREA
COLUMNS ROWS
1
25 9
2
11 9
3
9 13
4
25 7
11. Do you want to respecify the Fixed Screen Pointing Area?
[Y]
a. "Digitize lower left
corner of Fixed Screen Pointing Area."
(Defining the lower left corner of the active mole area.
Select the lower left hand corner of the active screen
pointing area located on the template.)
B. "Digitize upper right
corner of Fixed Screen Pointing Area."
(Defining the upper right corner of the active mole
area. Select the upper right hand corner of the active screen
pointing area located on the template.)
12. Do you want to specify the Floating Screen pointing Area?
[N]
13. The tablet is now configured for the AutoCAD template.
|
|
|