Switch Settings for 3xxxx Digitizer with Anvil 1000

Interactive Design Consultants
RR 5
Geneseo, IL  61254
(309) 944-8108

A.   Configure the Digitizer.

     1.   Use the pointing device to click on the CONFIG/EXIT key on the tablet menu strip using the pick button on the
           pointing device.  The CONFIGURATION light on the digitizer should turn on.

     2.   Click on the Bank A key.

     3.   As you place the pointing device on each button of the tablet 1 through 18, the POWER light will be either on or
          off. You can toggle the setting of any button by pressing the pick button.   The settings should be as follows:

          Bank A-1  1  0  0   0  1  1  1  1  1  0  0  0  1  0   1  0  1

          Bank B-0  0  0  1   0  0  0  0  0  0  0  0  0  0  0   0  0  1

           (1=POWER light on      0=POWER light off)

     4.   Click on the SAVE DEFAULT key to save these settings as the power-on default.

     5.   Click on the CONFIG/EXIT key to EXIT the CONFIGURATION.  The CONFIGURATION light on the digitizer
          should turn off.

     6.   Start Anvil 1000 and follow the instructions in the application manual to configure Anvil 1000 for use with the
           CalComp 3xxxx series digitizer setup as a CalComp 9100 Format #2.


 
© GTCO CalComp, Inc.                                                                                          Site Map  |  Legal Information  |  Web Site Comments Only